Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Journal of Peking University(Health Sciences) ; (6): 83-87, 2020.
Article in Chinese | WPRIM | ID: wpr-942145

ABSTRACT

OBJECTIVE@#To compare the registration accuracy of three-dimensional (3D) facial scans for the design of full-arch implant supported restoration by five methods and to explore the suitable registration method.@*METHODS@#According to the criteria, ten patients with maxillary edentulous jaw or end-stage dentition requiring implant supported restorations were enrolled in this study. A special rim with individual feature marks reflected appropriate occlusal relationship and esthetic characteristics was made for each patient. Both 3D facial scan data of natural laughter and with opener traction to expose the teeth or occlusal rim of each patient were acquired by facial scan and input to the digital analysis software Geomagic Qualify 2012. The dataset was superimposed by five different methods: seven facial anatomical landmark points alignment, facial immobile area alignment (forehead and nasal area), facial anatomical landmark points and immobile area combining alignment, facial feature points alignment, facial and intraoral feature points alignment with the same local coordinate system. The three-dimensional deviation of the same selected area was calculated, the smaller the deviation, the higher the registration accuracy. The 3D deviation was compared among the three registration methods of facial anatomical landmark points, facial immobile area alignment and the combination of the above two methods. Friedman test was performed to analyze the difference among the three methods (α=0.05). The effect of the aid of the facial and intraoral feature points were evaluated. Paired t test were performed to analyze the difference (P<0.05).@*RESULTS@#The average three-dimensional deviation of the selected area after alignment with the facial anatomical landmarks was (1.501 2±0.406 1) mm, significantly larger than that of the facial immobile area best-fit alignment [(0.629 1±0.150 6) mm] and the combination of the two methods[(0.629 1±0.150 6) mm] (P < 0.001). The aid of the facial feature points could significantly reduce the deviation (t=1.001 3, P < 0.001). There was no significant statistical difference in the remaining groups.@*CONCLUSION@#The forehead area of the 3D facial scan can be exposed as much as possible. The establishment of facial characteristic landmark points and the use of the invariant area alignment can improve the accuracy of registration. It should be clinically feasible to apply three-dimensional facial scan to the design of full-arch implant supported restoration with the registration of the immobile area on the face especially the forehead area.


Subject(s)
Humans , Computer-Aided Design , Imaging, Three-Dimensional , Jaw, Edentulous/diagnostic imaging , Maxilla/diagnostic imaging , Radionuclide Imaging
2.
Journal of Peking University(Health Sciences) ; (6): 136-144, 2019.
Article in Chinese | WPRIM | ID: wpr-941783

ABSTRACT

OBJECTIVE@#To investigate the oral hygiene status of edentulous patients with locator attachments implant overdentures (IOD) and to analyze the relationship among daily hygiene behavior, oral hygiene status and peri-implant diseases.@*METHODS@#Edentulous patients who received IOD treatment with locator attachments from January 2012 to May 2016 were recruited. Clinical and radiographic examinations were conducted to assess the peri-implant tissue status. Modified plaque index (mPLI), sulcus bleeding index (SBI), gingival index (GI), and probing depth (PD) were recorded and peri-implant marginal bone loss (MBL) was measured using paralleling projection technique. Patients' peri-implant oral hygiene maintainence habits were investigated. The correlation between peri-implant diseases and oral hygiene status and behaviors was analyzed.@*RESULTS@#Fifty patients (125 implants) with an average follow-up time of 22 months (6-54 months) were enrolled. The mean values of mPLI, SBI, and GI were 1.4±1.2, 0.8±0.7, and 0.7± 0.6, respectively. Average PD was (2.2±0.7) mm. Mesial and distal maginal bone resorptions were (1.1±1.1) mm and (0.9±0.9) mm, respectively. The prevalance of mucositis and peri-implantitis of the implants were 49.6% and 0. The prevelance of mucositis in the patients with poor oral hygiene (mPLI≥2) was 11.9 times as much as that of those with adequate oral hygiene (mPLI<1). The patients who performed oral hygiene procedure on attachments at least twice a day achieved much lower mPLI scores than those who cleaned less than twice a day.@*CONCLUSION@#Oral hygiene condition in the group of patients with implant overdentures was poor, and it contributed to increased risk of peri-implant mucositis. The prevelance of musositis of the paitients with poor oral hygiene was 11.9 times as much as that of those with proper oral hygiene. Patients wearing IOD should pay more attention to the hygiene of the attachments.


Subject(s)
Humans , Dental Implants , Dental Prosthesis, Implant-Supported , Denture, Overlay , Longitudinal Studies , Mandible , Oral Hygiene
SELECTION OF CITATIONS
SEARCH DETAIL